二氧化碳回收工廠(CBU)是以各種燃料如柴油、重油、煤油、天然氣通過燃燒、洗滌、吸收、解析、分離等工藝技術(shù)完成的。系統(tǒng)采用集中控制,確證系統(tǒng)安全、穩(wěn)定,所有儀器、儀表都預(yù)裝在殼塊內(nèi),便于運輸
、減少現(xiàn)場安裝、調(diào)試時間。
二氧化碳回收工廠產(chǎn)量:25-1000 kg/hr,其他產(chǎn)量另行設(shè)計。
系統(tǒng)是基于MEA冷卻吸收和加熱解析原理,煙氣首先通過堿液清洗冷卻,去除二氧化硫,再通過煙氣風(fēng)機將煙氣進入MEA吸收塔進行吸收,殘余氣體排放到大氣,此時吸收塔MEA吸收二氧化碳變成富液通過貧富換熱器進行能量回收,然后進入解析塔后解析出二氧化碳,解析塔內(nèi)MEA釋放二氧化碳后就成貧液,通過貧液泵進入貧富換熱器進行能量回收,貧液冷卻又回到吸收塔進行吸收,完成循環(huán)。
從解析塔釋放出的二氧化碳氣體通過二氧化碳冷卻器冷卻,進入高錳酸鉀塔進行凈化,凈化后的二氧化碳氣體被二級二氧化碳壓縮機壓縮到16bar,進行脫水干燥到露點-60℃,再通過活性炭吸附異味,然后通過二氧化碳管式換熱器冷卻到-30℃,進行液化。
匹配二氧化碳管式換熱器液化冷凍機以R22為冷凍劑,自動控制二氧化碳液化溫度。
液態(tài)二氧化碳通過深冷液化進入絕熱二氧化碳儲罐儲存。
例:生產(chǎn)能力:40TPD消耗
電:400 KW/H
高錳酸鉀:0.44 kg/hr
冷卻水:1.50 m3/hr
水洗塔水消耗:0.01 m3/hr
蒸汽:壓力:4-5bar
溫度:170-180℃
汽量:2,100kg/hr
CO2 Generating Plant (CBU) is based on combustion of various fossil fuels such as diesel oil, heavy oil, kerosene or natural gas. Through appropriate combustion, scrubbing, absorbing, stripping and separation technology.The plants are supplied with a control panel, which ensures continuous trouble-free operation. All instruments installed on the skids are wired to junction boxes prior to shipment and thus reducing installation and commissioning time on site.CO2 Generating Plant Standard Sizes: 25-1000 kg/hr-other sizes available on request.
The plant is based on combustion in the MEA heater unit. By means of washing with soda lye in a flue gas,Scrubber the flue gas is cooled and any sulphur dioxide is removed. From the flue gas scrubber, the flue gas is led through the absorber by means of an exhauster where the CO2 content of the flue gas is absorbed in a MEA (Monoethanolamine) solution. The gas residue is exhausted. The CO2 rich MEA solution is preheated in the rich/lean solution heat exchanger before it is pumped to the stripper where by further heating CO2 is released. The stripped lean MEA solution is led from the stripper through the rich/lean solution heat exchanger and the MEA cooler back to the absorber.
The CO2 gas is cooled in a gas cooler cleaned in a potassium permanganate(PPM) scrubber and led to theCO2 compressor, which compresses the gas in two stages to approx. 16 bar(g).To allow condensation the CO2 gas is dried in a dehydrator to a dew point of abt. -60℃. The CO2 is then passed through a carbon filter for removal of odors.The purified and dried gas is condensed in a multitube heat exchanger at a temperature of about-30℃.
The matching refrigeration plant is equipped with an freon compressor. The refrigeration plant maintains the correct operating pressure in the CO2 condenser.
The liquid deep-cooled CO2 is led to an insulated CO2 storage tank.
Capacity 40TPD
Power Total Connected 400 KWH
Chemicals(KMnO4) 0.44 kg/hr
Cooling water Evaporation Loss {@ 32 ℃(2.5-3.0 kg/cm2(g) &600m3/hr} 1.50 m3/hr
Make-Up Water for CO2 Scrubber 0.01 m3/hr
Note: Steam@4-5 bar(g) at a temperature of 170-180 Cwill be required@2,100kg for 1 hour.